Saab 9-5
+ Cars Saab 9-5
+ Controls and operation receptions
+ Options and car routine maintenance
+ The engine
- Systems of cooling of the engine, heating, ventilation and air conditioning
+ System of cooling of the engine
+ Systems of heating, ventilation and air conditioning
+ The power supply system and release of the fulfilled gases
+ Systems of an electric equipment of the engine
+ Manual box of a gear change
+ Automatic transmission
+ Coupling and power shafts
+ Brake system
+ Suspension bracket and steering
+ Body
+ Onboard electric equipment
|
Systems of cooling of the engine, heating, ventilation and air conditioning Specifications
System of cooling of the engine
Temperature dependence of resistance of the gauge of ignition (доп. A heater)
Temperature dependence of resistance of gauges of temperature ОЖ (доп. A heater)
|
The current consumed by fans of a radiator on high//low turns, And |
|
23//15
|
|
14//9
|
| Resistance of the resistor of low turns of the fan, Ohm |
0.33 10 %
|
| Temperature of opening of the thermostat, hailstones. |
89 2
|
| Boiling point |
131 hailstones. At 1.4 атм
|
| Temperature of transition of an arrow of the index of temperature ОЖ in a red zone, a hailstones |
129 2.5
|
| Pressure of operation of the valve of a cover of a broad tank, атм |
1.4 1.5
|
|
Temperature of inclusion of the fan of a radiator on high//low turns, hailstones. |
|
(100//113) 2
|
|
(97//107) 2
|
|
Temperature of deenergizing of the fan of a radiator on high//low turns, hailstones. |
|
(96//109) 1
|
|
(93//103) 1
|
| Greasing of sealing rings and epiploons of the water pump |
Gleitmo 805
|
Systems of heating, ventilation and air conditioning
Dependence of target pressure of the gauge of pressure of system K/V on pressure
| The maximum admissible working pressure of an additional heater, атм |
2.5
|
| The minimum water stream through an additional heater, л/ч |
450
|
| Теплоотдача an additional heater in a mode HIGH//LOW, kw |
5//2.4
|
| Fuel consumption by an additional heater in a mode HIGH//LOW, л/ч |
0.62//0.30
|
| Maximum//normal consumption of a current by the circulating pump at pressure 12 In, And |
1.6//0.8
|
| Turns of the fan of a heater in a mode HIGH//LOW, rpm |
(8000//4500) 400
|
| Coolant type |
R134a
|
| Quantity of a coolant, гр. |
875
|
| Temperature dependence of resistance of the gauge of temperature of system K/V |
|
|
Temperature, hailstones.
|
Resistance, clod
|
|
|
2.66
|
|
|
4.2
|
|
|
6.25
|
|
|
7.8
|
|
|
9.9
|
|
|
12.7
|
|
|
16.3
|
|
|
18.0
|
|
|
21.1
|
| Pressure of a food of the gauge of pressure of system K/V, Vteploobmennika, Ohm |
5
|
| Resistance э/м the valve отсечки |
43 49
|
| Resistance of windings of 1 and 2 step-by-step engines of system ACC (between plugs 1 and 3, and also 4 and 6), the Ohm |
100
|
Compressor K/V
Temperature dependence of resistance of the gauge of temperature of air in system ACC salon
| Type |
Denso 7SBU16, piston, with variable volume
|
| Cylinder volume, sm 3 |
161
|
| Type of refrigerator oil |
Synthetic гликолевое oil P.A.G.
|
| Volume of refrigerator oil in the new compressor, ml |
145
|
| Range of speeds, rpm |
750 8000
|
| Temperature of operation of protection against an overheat in э/м муфте, hailstones. |
184
|
| Люфт э/м муфты, mm |
0.5 0.15
|
| Pressure of opening//safety valve closing, атм. |
39//more than 34
|
Efforts of a tightening of carving connections, Nm
Cooling system
| Hollow bolt of fastening перепускной tubes to the inlet pipeline |
8
|
| Hose clip on перепускной to a tube |
8
|
| Fixture of the inlet pipeline of engines V6 |
20
|
| Fixture of the fan of a radiator |
8
|
|
Fixture of the water pump |
|
22
|
|
25
|
| Nut of fastening of a cooler of impellent oil (4-cylinder engines) |
10
|
| Fixture of a pulley of the water pump of engines V6 |
8
|
| Fixture of a pulley of pump GUR of engines V6 |
20
|
| Fixture натяжителя a belt of a drive of auxiliary units of engines V6 |
40
|
| Fixture of pump GUR of 4-cylinder engines |
24
|
| Fixture of the case of the thermostat of 4-cylinder engines |
22
|
| The thermostat of engines V6 |
20
|
| Fixture of a tube of cooling to the water pump of 4-cylinder engines |
10
|
|
Hollow bolt of fastening of a tube of cooling турбокомпрессора |
|
25
|
|
20
|
| Hollow bolt of fastening of a tube of ventilation картера to the inlet pipeline |
24
|
|
Thermofilter fixture |
|
24
|
Counternut (4-cylinder engines)
|
20
|
|
22
|
System K/V
| Bolts of fastening of compressor K/V |
24
|
| Fastening of hoses К/В to the compressor |
20
|
| Connections PAD to a receiver |
8
|
| The broad valve |
5
|
| Connections of hoses PAD to the broad valve |
8
|
| Connection низконапорной tubes between the broad valve and the compressor |
8
|
| Connection высоконапорной tubes between a receiver and the broad valve |
8
|
| The pressure gauge |
7 9
|
|
|